An installation of 3 of our FRENIC-Ace inverters and an HMI with connection via MODBUS was implemented in a restaurant in Croatia to offer customers a 360º view of the city. The task was to control the motors that are simultaneously rotating the restaurant platform, avoid any failures, and analyze and collect feedback of the application.
Our inverters control 3 of their motors, offering power control, protection against failures, speed control and maintenance warnings. Meanwhile, our HMI gives access to analytic data like current, temperature, and more at any moment.
Cleaning machines for kitchens, heaters, and air conditioners have an electric brushing solution which enters deep into ventilation ducts. Their rotating, flexible shafts must adapt perfectly to their environment without causing any damage. Fuji Electric installed our FRENIC-Mini C2 inverters into those cleaning machines, as well as our Monitouch Technoshot HMI screens.
The HMI replaced all manual keypads and push buttons and therefore modernized the machines significantly. With the FRENIC-Mini C2 and its quick response torque limitation, the cable inside the hose as well as the duct is well protected. In addition, the StopGo system stops the motor way before any breakdown can occur!
We installed our FRENIC-MEGA inverters in a garbage recycling shredder that has 2 motors of 132 kW, mechanically coupled in the same axis. The main requirements in this application were a high starting torque (overload up to 200%), a control in the load imbalance and the maintenance of speed during the process.
With our FRENIC-MEGA and its “droop-control” function, we can keep the load unbalance to a minimum. This represents a machine process control without stops, thus prolonging its maintenance!
We installed our FRENIC-Ace, 3-phase 400 V, 1.5 to 2.2 kW into a textile machine in Italy. The challenge was to control a permanent magnetic synchronous motor (PMSM) in open loop and to find a function to stop the machine with PID function in case of input phase loss.
Our solution provides a low voltage ride-through function, a best PMSM control with static pole-tuning at starting, and which has CANopen built-in.
For this installation, Fuji Electric developed a complete cabinet with EPLAN schematics. 2 FRENIC-Ace inverters with our special software for solar pumping (CLI-SOL) were installed: 1 inverter of 7.5 kW for submersible pumps (irrigation pump) and 1 inverter of 2.2 kW for water rotation pump of the lake.
A third standard FRENIC-Ace inverter was also installed for synthetic main supply, which allows the connection of any other external 230/400V AC load.
Our HMI Monitouch Technoshot allow a remote connection through VNC, so you can watch, read and save the information of the inverter and PLC of your installation or machine. This is an installation of diamond wire saw machine for cutting and processing natural stone in quarries, such as granite, marble, slate, onyx, etc.
As well as for industrial materials such as metals, composites, glass, PVC. Now our customer could upgrade and go from a totally manual process (with buttons) to a more automated and visual process!
When doing maintenance on an Uninterruptible Power Supply and its auxiliary equipment, keeping it clean is one of the main objectives. Dirt, dust, sawdust, and metal filings are just some of the pollutants that technicians see in UPSs, even when installed in seemingly clean environments. These substances can cause failures when they contaminate the contacts of relays and contactors, and conductive material can cause short circuits and malfunctions on printed circuit boards (PCBs).
At least once a year, make sure your UPS gets cleaned including a good vacuuming with a non-conductive hose and attachments. Never use a blower or compressed air! These methods can blow contaminants deeper into the unit, causing real troubleshooting headaches if and when they finally do cause issues. Use lint-free rags lightly damp with a nonflammable and fast-drying solvent for heavy deposits, and soft brushes around delicate components and connectors. Always perform cleaning work on equipment that is offline, and de-energized and with the proper personal protective equipment (PPE) such as goggles, gloves, aprons, and respirators as necessary.
Know Your Pipe and Don't Guess
Know your pipe and don't guess! This includes the customer knowing their liner and its thickness. Many customers don't know their pipe's exact specifications, but by measuring circumference and looking for a schedule embossment on a fitting, as well as referencing a pipe resource is usually a good solution.
It is also something they can research with a system engineer ahead of a flow survey or fixed installation. To that point, they could even program the measurement point(s) on the bench in air conditioning before going in the field.
Optimize Your Inverters
Get Your Installation Right
Surveying the intended installation location for straight run, and selecting a valid installation point is one of the most important tips we could offer. That is after vetting Transit Time Ultrasonic technology for the macroscopic application. This is by far the biggest battle we have in the field, even when we try to get this information upfront in our application work.
It seems that people use the basic rule of 10D up/5D down and apply it to all situations, or make no straight run considerations at all. I would highlight the need for additional straight runs for the plumbing situations that poses the biggest obstacles for us. The biggest being pumps, two elbows out of plane, valves, and T fittings. The trick is to portray this without evoking fear, just to bring them to conscious thought.
Ring Compressors & Blowers for Pressure, Vacuum, and Airflow
Pressure
Systems for Waste Water Treatment and Aquaculture rely on Fuji Electric Regenerative Blowers to provide reliable pressure. For Waste Water applications, our blowers provide airflow and pressure for aeration of Waste Water Systems. In Aquaculture, our blowers provide airflow for pressure application in the aeration tanks for Shrimp and Fish.
Vacuum
Applications for Pneumatic Tube Systems and Hold Down Applications for Milling & Cutting utilize Fuji Electric Regenerative Blowers for its vacuum capabilities. Fuji Electric Blowers provide reliable pressure and vacuum as the driver for Tube systems. Our regenerative blowers also provide vacuum for hold down applications for milling and cutting applications.
Airflow & Aeration
When it comes to efficient and reliable airflow, industries such as Metal Plating and Commercial Spas & Hot Tubs use our blowers. Fuji Electric Regenerative blowers provide aeration for plating tanks, mixing tanks and rinsing tanks. Our blowers also provide aeration for commercial spas and hot tubs.
AC Drives for Residential Elevators
We understand you need products to be reliable and manufactured to the highest quality standards. In this case, when a large volume manufacturer of residential elevators was experiencing widespread field failures with their current supplier of the VFD used in their application, they immediately sought out an alternative solution.
Our engineering team and resources at the customer worked in concert to provide a comprehensive solution that required meeting the highest quality standards in their industry. A solution was provided and tested over 800,000 cycles. Several competitor’s products failed during the testing process. Fuji Electric was selected as their primary source for their production requirements and adopted as their standard of choice. At Fuji Electric, we pride ourselves on manufacturing products that exceed our customers expectations.
HMI for Oil & Gas
Compact size and shallow mounting depth make Fuji Electric operator interfaces ideal for installation in harsh environments, and for many factory automation applications. Did you know Fuji Electric HMI’s are utilized in the Oil and Gas – Test and Measurement industry? We work with companies who selected several manufacturers to test; several of those failed to pass their stringent harsh duty requirements.
After months of field operation, Fuji Electric was chosen as their preferred choice to meet their application requirements. Since then, we have deployed several thousand units in the field, operating in the most extreme temperature climates. When choosing Fuji Electric for your HMI requirements, you can be assured of receiving a product that is suitable for just about any industrial environment!
Regenerative Blowers for Spas & Hot Tubs
Most spas and hot tubs require regenerative blowers to provide the pressure and flow needed to agitate the water. Here are your Do’s & Don’ts for your Commercial Spa to operate smoothly:
Do’s
1. Use a licensed electrician to install your blower.
2. Use a Pressure relief valve.
3. Use a Hartford loop at least 18 inches above the water level of the spa.
4. Install the blower as close to the spa as possible.
5. Install the blower in a weatherproof house or enclosure.
6. Install a check valve as close to the spa as possible.
7. Install an Inlet Filter on the blower.
Don’ts
1. Don’t install the unit lower than the water level of the spa.
2. Don’t allow water into the blower. Water will damage the blower and void the warranty
Pressure Transmitters for all Industrial Areas
The pressure sensor should be chosen based on the fluid to be measured and the conditions of service of the application. It is necessary to define:
Semiconductors that Keep Your Production Line Moving
Welding is a critical activity used on many modern production lines. So, when downtime hits, your entire line can go down. Our IGBT modules have been specifically designed to maximize uptime so you don't miss a step.
Low Loss
Reduce inverter loss by 10% and chip temperature by 1 OC compared with the 6th generation V series EP3 Package (75A at fc = 8kHz).
Miniaturization
An approximately 36% smaller footprint has been achieved by reducing power loss and improving heat transfer
High Temperature Operation
Up to 35% more output than the previous generation. A 2x improvement in power cycle capability.
Semiconductor Reliability Where You Need It Most!
Your UPS prevents system shutdown during power outages by relying on IGBT modules. Our IGBT modules offer the right characteristics to keep everything up and running.
High Reliability
Achieves continuous operation at 175°C through chip optimization and heat resistance of package to minimize field failures.
High Efficiency
Thinning the thickness and miniaturizing the structure of the IGBT chip and diode chip reduces power losses during inverter operation.
Fuji Electric XR Series Digital Datasheet
X Series Dual XT IGBT Modules
NEW Instrumentation & Control Product Solutions
Ultrasonic Flowmeter for Steam
NEW G-Twin UL Plug-In Series Product Video
NEW Ring Compressor & Blower Product Solutions
NEW UPS Product Solutions