Human-Machine Interfaces (HMIs) serve as the bridge between operators and industrial equipment. Whether controlling a manufacturing line, monitoring a water treatment facility, or managing an HVAC system, the effectiveness of an HMI can significantly impact productivity, safety, and operational efficiency.

Unfortunately, not all HMI screens are designed with the operator in mind. Overly complex layouts, excessive colors, and poorly organized information can lead to confusion, slower response times, and increased risk of operator error.

Effective HMI design focuses on clarity, usability, and situational awareness. By following proven design principles for layout, color usage, and workflow organization, engineers and system integrators can create interfaces that help operators make faster, more informed decisions.

Why HMI Design Matters

An HMI is much more than a graphical representation of equipment. It is a decision-making tool.

Operators use HMIs to:

When information is presented clearly, operators can quickly understand system status and take appropriate action. Poorly designed interfaces can have the opposite effect, increasing workload and delaying responses during critical situations.

In industries where downtime, safety incidents, or product quality issues carry significant consequences, effective HMI design becomes a valuable operational asset.

Start with the Operator’s Workflow

One of the most common HMI design mistakes is building screens around the equipment instead of the operator.

Engineers often organize screens based on how systems are wired or programmed. Operators, however, think in terms of tasks and processes.

Before designing any screen, ask:

The answers should guide the structure of the interface.

A well-designed HMI supports the natural workflow of the operator rather than forcing operators to search through multiple screens to find critical information.

Design Around a Clear Screen Hierarchy

Modern HMI design often follows a hierarchical structure that allows users to move from high-level system visibility to detailed diagnostics.

Level 1: System Overview

The primary screen should provide a high-level overview of the entire process.

This screen should answer questions such as:

The overview screen serves as the operator’s dashboard and should be accessible at all times.

Level 2: Area or Process Screens

These screens provide more detailed information about specific process areas, machines, or production lines.

Examples include:

Level 3: Equipment Detail Screens

These screens display detailed operating information for individual assets.

Examples include:

Level 4: Diagnostic and Configuration Screens

The most detailed screens should be reserved for troubleshooting and engineering functions.

This layered approach helps prevent information overload while allowing operators to drill down when necessary.

Keep Screen Layouts Clean and Organized

A cluttered screen increases cognitive load and makes it more difficult for operators to identify important information.

Effective layouts typically include:

Consistent Navigation

Navigation buttons should remain in the same location throughout the application.

Common placements include:

Consistency helps operators build familiarity and reduces training requirements.

Logical Grouping

Related information should be grouped together.

For example:

Grouping information reduces the amount of visual searching required.

Adequate White Space

White space is not wasted space.

Strategic spacing improves readability and helps separate different functional areas of the screen.

Crowded interfaces often appear more complex than they actually are.

Use Color Purposefully

One of the biggest mistakes in HMI design is using too many colors.

Many older systems display equipment in bright reds, greens, blues, yellows, and purples simultaneously, creating a visually overwhelming experience.

Modern high-performance HMI design takes a different approach.

Use Neutral Colors for Normal Conditions

Normal operating equipment should typically appear in neutral tones such as:

When everything is colorful, nothing stands out.

Reserve Bright Colors for Abnormal Conditions

Color should attract attention only when necessary.

Common conventions include:

Color

Typical Meaning

Red

Critical alarm or fault

Yellow/Amber

Warning or abnormal condition

Green

Running or active status

Blue

Operator action required

Gray

Inactive or unavailable

By minimizing color use during normal operation, alarms become immediately noticeable.

Prioritize Situational Awareness

The primary purpose of an HMI is helping operators understand what is happening right now.

Good situational awareness means operators can quickly answer:

To support situational awareness:

Display Key Performance Indicators (KPIs)

Important metrics should be visible without navigating through multiple screens.

Examples include:

Highlight Trends

Operators often gain more insight from trends than from individual values.

Trend displays help identify:

Historical context supports better decision-making.

Simplify Alarm Management

Poor alarm design can overwhelm operators during abnormal events.

Best practices include:

Prioritize Alarms

Not every event should be treated as critical.

Classify alarms according to severity:

Avoid Alarm Flooding

Excessive alarm notifications can cause operators to ignore important alerts.

Alarm rationalization helps ensure only meaningful events trigger notifications.

Provide Context

An alarm should explain:

The goal is to help operators respond, not simply notify them.

Optimize for Touchscreen Operation

As touchscreen HMIs become increasingly common, interfaces should be designed accordingly.

Use Larger Touch Targets

Buttons should be large enough for accurate operation while wearing gloves if required.

Avoid Overcrowding Controls

Closely spaced buttons increase the risk of accidental selections.

Limit Excessive Data Entry

Whenever possible:

Reducing manual entry speeds operation and reduces errors.

Standardize Graphics and Symbols

Consistency improves usability.

Operators should not need to interpret different symbols for identical equipment across screens.

Standardize:

Consistent graphics reduce training time and improve operator confidence.

Test with Real Operators

One of the most valuable steps in HMI development occurs before deployment.

Involve actual operators during design reviews.

Ask them:

Operators often identify usability issues that engineers may overlook.

Testing early can prevent costly redesigns later.

Common HMI Design Mistakes

Avoid these frequently encountered issues:

Eliminating these problems often leads to immediate improvements in usability.

Final Thoughts

A well-designed HMI does more than display information—it helps operators understand processes, identify problems, and make informed decisions quickly. Effective HMI design combines clean layouts, thoughtful color usage, logical workflows, and clear navigation to create an interface that supports both productivity and safety.

By focusing on operator needs, minimizing visual clutter, and emphasizing situational awareness, organizations can build HMIs that improve efficiency, reduce errors, shorten training time, and enhance overall system performance.

In today’s increasingly automated facilities, user-friendly HMI design is not simply a convenience—it is an essential component of successful industrial operations.