Specifications
- Product Series:Â FRENIC-MEGA (G1)
- Family Series:Â Fuji Drives, Mega Series
- HP Ratings
- LD, 3-Phase:Â 1000
- HD, 3-Phase:Â 900
- Output Volt Range:Â 380-480
- Output Rated Current, 3-Phase
- LD, 3-Phase: 1370
- HD, 3-Phase:Â 1170
- Amps, 1-Phase
- LD, 1-Phase: Check Instruction Book
- HD, 1-Phase:Â Check Instruction Book
- Overload capability
- LD, 3-Phase: 120% 1min.
- HD, 3-Phase:Â 150% 1min., 200% 3s
- Watt loss @ Running
- LD, 3-Phase: 13500
- HD, 3-Phase:Â 11900
- Watt loss at stop:Â 467
- DCR
- DCR PN#:Â DCR4-710C
- DCR Watt Loss:Â 600
- Inverter Efficiency at rated(Hz), rated(A)
- Low carrier frequency (2kHz):Â 0.98
- High carrier frequency:Â 0.98
- Nominal Input Voltage, frequency:Â 460, 50/60Hz
- Input Volt Range:Â 380-480, +10 to -15%
- Output Volt Range:Â 0 – 480V, 3-Phase
- Max output Frequency:Â 500 Hz
- Digital Input:Â 7(9)*
- Analog Inputs:Â 3
- Transistor outputs:Â 4
- General purpose relay output:Â 1
- Alarm relay output:Â 1
- Braking
- LD, Torque [%]:Â 7 to 12%
- HD, Torque [%]:Â 10 to 15%
- Duty Cycle LD, %ED:Â –
- Duty Cycle HD, %ED:Â –
- Braking Unit Type:Â
- Braking Unit QTY.:Â 3
- Built-in braking resistor:Â DB220-4C
- Braking Resistor QTY.:Â 3
- Enclosure
- Standard:Â IP00
- Cooling:Â Fan
- Weight/Mass [lbs.(kg)]:Â 1170
(530) - Drawing Open Chassis:Â ROA701017
- Dimensions H x W x D (inches):Â 61.02 x 39.37 x 19.69
- NEMA Kit
- NEMA/UL Type 1:Â NEMA1-630G1-4
- Drawing NEMA1:Â ROA701040
- Option Cards, Communication Card
- Modbus RTU:Â Standard
- DeviceNet:Â OPC-G1-DEV
- Profibus:Â OPC-G1-PDP
- Profinet:Â OPC-PRT2
- CC-Link:Â OPC-G1_CCL
- Ethernet/IP:Â OPC-G1-ETH
- Modbus TCP:Â OPC-G1-ETH
- BACnet/IP:Â OPC-G1-ETH
- CANOpen:Â OPC-G1-COP
- T-Link Communications Card:Â OPC-G1-TL
- Multiprotocol Ethernet Interface:Â OPC-G1-ETH
- Option Card, Input/Output
- 115VAC I/O Card – Remote Mount:Â OPC-115V
- Relay Output Card:Â OPC-G1-RY
- Digital Input Interface Card:Â OPC-G1-DI
- Digital Output interface card:Â OPC-G1-DO
- Analog Input / Output Interface Card:Â OPC-G1-AIO
- PG Interface Card (5V):Â OPC-G1-PG2
- PG Interface Card (12V):Â OPC-G1-PG
- PG Synchronization Card:Â OPC-G1-PG22