What is the plating material for soldering terminals? (PINS?)

Please contact Fuji Electric Corp. of America or your local sales representative or distributor to answer your question.

What is the time dependency of I2t (IFSM)?

Values of I2t and IFSM described in the specification/data sheet shall be the guaranteed value for the half-sine 10ms surge current waveform. For I2t and IFSM for other wavefrom or condition, please contact us.

What are the values of wiring resistance and inductance in the package?

“The resistance of the main current wiring in the module can be calculated from the values of VCEsat and VF of the terminal and the chip shown in the data sheet. Example: 2MBI600XNE120-50 (Tvj=25oC, Ic=600A) VCEsat (terminal) = 2.20V, VCEsat (chip)=1.45V Internal wiring resistance Rint = (2.20V-1.45V)/600A=1.25mΩ Please contact us for the value of internal […]

What is the difference between a beige module case and a black module case.

The color is not important from technical point of view. All elder modules including the 5th generation module (U Series) are black. Starting with the 6th generation module (V Series) a natural color (beige) is used to easyly identify the RoHS compliant modules.

VCEsat and VF are given for terminal and chip. How can we use them properly? (What is the meaning?)

“VCEsat and VF of the terminal are ON voltages measured on the main terminals and include voltages induced on the internal wiring of the module. Use them as a reference when On voltage is measured on the terminal. On the other hand, VCEsat and VF characteristics of the chip indicate IN voltage closest to the […]

Once the protection function in Small IPM is triggered and the system stops, how can it be reseted: automatic reset or latch?

It will be reset automatically. After the alarm output period tFO elapsed and the cause of failure has been removed, the protection will reset automatically.

Does an alarm occur, if the PWM signal is not transmitted to the control input terminal (Vin: High Level) of the V series IPM?

Since the TjOH protection and the UVLO protection are independent from input signals, an alarm signal will be issued when overheat or power supply voltage drop occurs. For Short Circuit (SC) and Over Current (OC) protection will be activated when the input signal is IGBT ON (Vin: Low Level).

Why do I receive the error message "Input value is outside of the setting range." when entering the calculation conditions in the Fuji IGBT loss simulator?

The simulator is based on data obtained by measurement results. The measured values are within the range of representative characteristics described in each data sheet. Input of conditions that are away from actual measurement range will create an error.

There is a description "package no. M***, P*** in Fuji Electric semiconductor catalog. What does it mean?

“M***: IGBT module product P***: IPM product”

Which snubber capacitors are recommended for modules (M403, M404) used in a 3-level inverter?

There are several snubber capacitors with different withstand voltages and capacitances which meet the main terminal pitch. Please contact RUBYCON CORPORATION.