Can we apply an IGBT module directly to a heat sink?

No, prior to using an IGBT module, please apply thermal grease (compound) on the surface of a heat sink and module before layering. This will reduce the contact thermal resistance. For details, refer to Application Manual Chapter 6-3.3 or Mounting Instruction.

Where are the chips located internally?

Please contact Fuji Electric Corp. of America or your local sales representative or distributor to answer your question.

How do I measure the case temperature (Tc) for an IGBT module?

The following illustrates an example of how to measure case temperature (Tc). One method is to make a groove on a copper base or a heat sink of an IGBT module to embed a thermocouple. Please fill the groove with highly thermally conductive paste to secure the thermocouple and attain even thermal diffusion.

What is the difference between Tj(max) and Tj(op)?

The maximum allowable temperature for the chip during conventional continuous operation is specified in Tj(op). Please ensure the maximum chip temperature stays at or under Tj(op) during conventional continuous operation. The maximum allowable temperature for a chip during short-term overload or abnormal operation is specified inTj(max).

How do I estimate the junction temperature (Tj)?

Junction temperature can be estimated based on generated losses and thermal resistance Rth(j-c). For details, refer to Application Manual Chapter 6-2.1. We provide a free software to calculate IGBT’s temperature at 2-level inverter, 3-level inverter, and chopper circuits. This software can be downloaded here.

What is the acceptable range of case temperature (Tc) for an IGBT module?

Refer to the “Maximum Ratings: Case temperature” section in the data sheet.

What is the case temperature (Tc)?

Case temperature (Tc) is the temperature on the module copper base surface right under a semiconductor chip where the temperature is the highest.

What is the junction temperature (Tj)?

Junction temperature is the temperature at joints on a semiconductor chip.

What functions do the IGBT Simulator have?

The IGBT Simulator can estimate the power loss and temperature for a 3-phase 2-level inverter circuit, 3-phase 3-level inverter circuit, and chopper circuit of an IGBT and FWD. It can also calculate loss and temperature under variable inverter operation conditions such as output current and switching frequency. Changes in loss and temperature when the load […]

How do I calculate IGBT losses?

Fuji provides a free software to calculate the IGBT losses. The following steps can be followed to obtain the figure. (1) Download our Loss Simulator (2) Launch our Loss Simulator (3) Enter data on the chip series, circuit configuration, voltage rating, and current rating. Select your model type. Click “”Next”” (4) Enter data on the […]