FRENIC-MEGA(G1): FRNF50G1S-2U
Technical Support During Business Hours:
(510) 403-7866
6:00 AM – 5:00 PM (PST)
Monday – Friday
Dial Ext. 1 – General Tech Support
Dial Ext. 2 – Parts, Repair, Warranty & Service
Customer Service:
(510) 403-7861
7:30 AM – 8:00 PM (EST)
Monday – Friday
Technical Support After Business Hours:
1-888-900-3854
24 Hour Support:
Monday – Friday
6:00 AM – 11:59 PM (PST)
Service 
Specifications
- Product Series: FRENIC-MEGA (G1)
 - Family Series: Fuji Drives, Mega Series
 - HP Ratings
- LD, 3-Phase: 0.5
 - HD, 3-Phase: 0.5
 
 - Output Volt Range: 200-240
 - Output Rated Current, 3-Phase
- LD, 3-Phase: 3
 - HD, 3-Phase: 3
 
 - Amps, 1-Phase
- LD, 1-Phase: Check Instruction Book
 - HD, 1-Phase: Check Instruction Book
 
 - Overload capability
- LD, 3-Phase: 120% 1min.
 - HD, 3-Phase: 150% 1min., 200% 3s
 
 - Watt loss @ Running
- LD, 3-Phase: 35
 - HD, 3-Phase: 35
 
 - Watt loss at stop: 23
 - DCR
- DCR PN#: –
 - DCR Watt Loss: –
 
 - Inverter Efficiency at rated(Hz), rated(A)
- Low carrier frequency (2kHz): 0.93
 - High carrier frequency: 0.91
 
 - Nominal Input Voltage, frequency: 230, 50/60Hz
 - Input Volt Range: 200-240, +10 to -15%
 - Output Volt Range: 0 – 240V, 3-Phase
 - Max output Frequency: 500 Hz
 - Digital Input: 7(9)*
 - Analog Inputs: 3
 - Transistor outputs: 4
 - General purpose relay output: 1
 - Alarm relay output: 1
 
- Braking
- LD, Torque [%]: 1.5
 - HD, Torque [%]: 1.5
 - Duty Cycle LD, %ED: 5
 - Duty Cycle HD, %ED: 5
 - Braking Unit Type: 
- Braking Unit QTY.: –
 - Built-in braking resistor: Built-in
 - Braking Resistor QTY.: –
  
 - Enclosure
- Standard: IP20
 - Cooling: Natural
 - Weight/Mass [lbs.(kg)]: 3.8
(1.7) - Drawing Open Chassis: ROA701001
 - Dimensions H x W x D (inches): 10.24 x 4.33 x 5.2
 
 - NEMA Kit
- NEMA/UL Type 1: NEMA1-0.4G1-24
 - Drawing NEMA1: ROA701018
 
 - Option Cards, Communication Card
- Modbus RTU: Standard
 - DeviceNet: OPC-G1-DEV
 - Profibus: OPC-G1-PDP
 - Profinet: OPC-PRT2
 - CC-Link: OPC-G1_CCL
 - Ethernet/IP: OPC-G1-ETH
 - Modbus TCP: OPC-G1-ETH
 - BACnet/IP: OPC-G1-ETH
 - CANOpen: OPC-G1-COP
 - T-Link Communications Card: OPC-G1-TL
 - Multiprotocol Ethernet Interface: OPC-G1-ETH
 
 - Option Card, Input/Output
- 115VAC I/O Card – Remote Mount: OPC-115V
 - Relay Output Card: OPC-G1-RY
 - Digital Input Interface Card: OPC-G1-DI
 - Digital Output interface card: OPC-G1-DO
 - Analog Input / Output Interface Card: OPC-G1-AIO
 - PG Interface Card (5V): OPC-G1-PG2
 - PG Interface Card (12V): OPC-G1-PG
 - PG Synchronization Card: OPC-G1-PG22
 
 
Have a question?

        


































					
					
					
					
					
					
					
					
					
					
					
					
					
					
					
					
					
					
					
					