“The resistance of the main current wiring in the module can be calculated from the values of VCEsat and VF of the terminal and the chip shown in the data sheet. Example: 2MBI600XNE120-50 (Tvj=25oC, Ic=600A) VCEsat (terminal) = 2.20V, VCEsat (chip)=1.45V Internal wiring resistance Rint = (2.20V-1.45V)/600A=1.25mΩ Please contact us for the value of internal […]
An installation of 3 of our FRENIC-Ace inverters and an HMI with connection via MODBUS was implemented in a restaurant in Croatia to offer customers a 360º view of the city. The task was to control the motors that are simultaneously rotating the restaurant platform, avoid any failures, and analyze and collect feedback of the application.