Single-Beam NDIR Gas Analyzer (ZPA)

Simultaneous and continuous measurement of up to 5 components among NO, SO2, CO, CO2, CH4, and O2in incinerators or boilers

  • Compact and lightweight: 19-inch rack mount
  • Built-in magnetic O2 sensor or optional galvanic O2 sensor
  • Optional functions include: atmospheric pressure compensation, RS-485 communication, automatic calibration, alarm output, O2 correction, and more.
  • Low maintenance

Specifications

Principle Non dispersive infrared sensor (single beam system)
O2 sensor: built-in magnetic or galvanic sensor, or external zirconia sensor (ZFK7)
Ranges NO: 0–200 ppm…5000 ppm
SO2: 0–200 ppm…10 vol%
CO2: 0–100 ppm…100 vol%
CO: 0–200 ppm…100 vol%
CH4: 0–500 ppm…100 vol%
Built-in galvanic O2 sensor: 0–10 vol%…25 vol%
Built-in magnetic O2 sensor: 0–5 vol%…100 vol% or 100–95 vol%
External zirconia O2 sensor: 0–5 vol%…25 vol%
No. of ranges Up to 2 ranges per component
Repeatability ≤ ±0.5% FS
Linearity ≤ ±1% FS
Zero drift ≤ ±2% FS per week
For NO and SO2 of ranges below 500 ppm, auto calibration is necessary before measurement.
Span drift ≤ ±2% FS per week
Response time (for 90%) 10–30 s (depends on ranges)
Analog output signal 4–20 mA DC or 0–1 V DC
Display Backlit LCD (Japanese, English, or Chinese available)
Instantaneous value, O2-corrected instantaneous value, O2 corrected average value, O2average
Range switching by key operation, automatic, or by external contact input (option)
Contact input (option) Voltage contact input (12–24 V DC, up to 15 mA)
Remote range-switching, auto-calibration remote start, remote hold, average reset
Contact output (option) SPDT relay contact (24 V DC/1 A)
Device error, calibration error, range identification, auto-calibration status, solenoid valve drive for auto-calibration, limit alarm, CO peak alarm
Atmospheric pressure correction (optional) Built-in option available
Standard functions Output hold, auto/manual range switching
Optional functions Auto calibration, auto calibration remote start, remote hold of output, range identification contact output, high/low limit alarm, O2correction, O2-corrected average values, average resetting contact input, CO peak alarm contact output
Communication (option) RS-485 (Modbus) (9-pin D-sub output): half-duplex, start-stop synchronization system
Gas inlet/outlet Rc 1/4 or NPT 1/4 internal thread
Purge gas flow rate 1 L/min (as needed)
Operating environment -5 to +45°C, RH90% or lower (non condensing)
Power supply voltage 100–240 V AC, 50/60 Hz
Power consumption Approx. 100 VA
Dimensions 133 (H) × 483 (W) × 382 (D) mm
Weight Approx. 11 kg
Conformity CE Marking

Sample gas conditions

Flow rate 0.5 L/min ±0.2 L/min
Temperature 0–50°C
Pressure ≤ 10 kPa
Dust ≤ 100 μg/Nm3 with particle size ≤ 0.3 μm
Mist Unallowable
Moisture Below the saturation vapor density at room temperature (non condensing)
Below the saturation vapor density at 2°C (non condensing) for NO, SO2, and CO of the range below 200 ppm
Corrosive gas HCl ≤ 1 ppm